Moisture Sensor for Mixers and Small Vessels

Hydro – Mix Flush mount, digital, microwave moisture sensor

moisture-sensors-for-mixer-vessels
moisture-sensors-for-mixer-vessels
Technical Specifications
Construction Body: Stainless Steel
Protection Ring : Hardened Steel
Faceplate: Ceramic
Moisture Range The sensor will measure up to saturation of material.
Material Penetration Approximately 75-100mm dependent on material.
Fixing The Hydro-Mix is secured to a fixing plate by a clamp ring. This allows the height of the sensor to be adjusted if necessary.
Operating Temperature 0-60 degrees C. The sensor will not measure in ice.
Analogue Outputs 2 Configurable 0-20mA or 4-20mA current loop source available for moisture and temperature. May also be converted to 0-10V DC.
Digital Inputs/Output 2 configurable digital signals are provided for batch average start/stop or for moisture / temperature multiplexing purposes.
Connections The sensor is fitted with a 10-way MIL-SPEC connector. A 4, 10 or 25 metre, 6 twisted pair cable pre-assembled for connection to a waterproof junction box is available.
Power Supply +15Vdc to +30Vdc. 4W
Digital (Serial) Communications Opto-isolated RS485 2-wire port. Uses Hydro – com communications protocol for read/write access to sensor parameters and values. Ethernet and USB interfaces are also available.

Features

  • Fully Temperature Compensated Measurement
  • Advanced Digital Technology
  • Easy to Interface
  • Replaceable Ceramic Faceplate
  • Measurement Modes
  • Wear Life
  • Sensor Configuration
  • Simple Power Requirements
  • Temperature Measurement
  • Measuring in the Mix
  • Calibration
  • Accuracy of Measurement